Basically as this product is supplied primarily as an IP camera to both the USA and UK operations the default is NTSC and Auto BNC output. Unfortunately this does not suit a UK analogue installation without changing some things. This can only be done via the web browser meaning that you must have access to a PC.
You can download the V-Cell Smart Manager discovery tool from here:
https://www.vicon-security.com/software-downloads-library/vicon-camera-software
Once installed this will show you the IP address that the camera is currently set to.
This should be changed so that it is in the same range as your PC or vice versa.
When you know the correct IP address put this into your Internet Explorer web browser and the camera menu should appear. You may be asked to download an ActiveX control which is needed to view a live stream.
For the UK set the Video mode to PAL - or for the USA NTSC
And Change the BNC mode to Manual and Video out to ON
Save your settings. The Camera will reset and then your analogue picture should appear.